User Tools

Site Tools


roco:roco-z21-en

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
roco:roco-z21-en [2025/12/21 11:21] – [Setup] rjversluisroco:roco-z21-en [2025/12/21 11:32] (current) rjversluis
Line 38: Line 38:
  
  
-===== Setup =====+=====Setup dialog=====
 {{:roco:z21-setup-en.png?500}}\\ {{:roco:z21-setup-en.png?500}}\\
 +
 +===== Connection =====
 +====Interface ID====
 +Command Station reference.\\
 +
 +====UniqueID====
 +Default 21, if left zero, to be used as [[:powerman-en#uid|Booster UID]].\\
  
 ====Hostname/IP-Adresse==== ====Hostname/IP-Adresse====
Line 48: Line 55:
  
  
 +=====Options=====
 ====Locomotives==== ====Locomotives====
 :!: //Only use this option in case locomotives are controlled by an external throttle which connects directly to the Z21/z21.//\\ :!: //Only use this option in case locomotives are controlled by an external throttle which connects directly to the Z21/z21.//\\
Line 62: Line 69:
  
 ====Booster events==== ====Booster events====
-This option must be activated, if Booster events should be received from the the z21 controller.  +This option must be activated, if Booster events should be received from the the z21 controller.\\ 
- \\+
 ====LocoNet detectors==== ====LocoNet detectors====
 This option should only be activated if RailCom detectors are connected to the LocoNet bus of the z21 controller.\\ This option should only be activated if RailCom detectors are connected to the LocoNet bus of the z21 controller.\\
 It activates OPC_MULTI_SENSE events. For more information see capital **9.5** //LAN_LOCONET_DETECTOR// in the Z21 Protocol Specs.\\ It activates OPC_MULTI_SENSE events. For more information see capital **9.5** //LAN_LOCONET_DETECTOR// in the Z21 Protocol Specs.\\
 **Note:** //Leave this option disabled in case no RailCom detectors are connected.//\\ **Note:** //Leave this option disabled in case no RailCom detectors are connected.//\\
- \\+
 ====multiMAUS==== ====multiMAUS====
 Check if the event is originated by the multiMAUS to signal Rocrail that it is a field event.\\ Check if the event is originated by the multiMAUS to signal Rocrail that it is a field event.\\
  
-====Program FB====+====Watchdog==== 
 +Check if the Z21 is online by sending every second a request.\\ 
 +If after the timeout in seconds no response came in, the Z21 is regarded as offline.\\ 
 +The Z21 will be re-initialized if it comes online again.\\ 
 + \\ 
 + 
 + 
 + \\ 
 + \\ 
 +=====Program FB=====
 {{ :roco:z21-10787.jpg?400}} {{ :roco:z21-10787.jpg?400}}
 Program a Roco 10787 sensor module.\\ Program a Roco 10787 sensor module.\\
Line 80: Line 96:
   - :!: Program address zero after the sensor module has acknowledged.   - :!: Program address zero after the sensor module has acknowledged.
  
-==== Switch time ====+===== Switch time =====
 Default output activation time for switches.\\ Default output activation time for switches.\\
 This value is only used in case the __**[[:switch-int-en#switch_time|Switch time]]**__ for a individual turnout is zero.\\ This value is only used in case the __**[[:switch-int-en#switch_time|Switch time]]**__ for a individual turnout is zero.\\
roco/roco-z21-en.1766312465.txt.gz · Last modified: 2025/12/21 11:21 by rjversluis