rocrailini-automode-en
Differences
This shows you the differences between two versions of the page.
| Next revision | Previous revision | ||
| rocrailini-automode-en [2024/12/21 08:17] – created - external edit 127.0.0.1 | rocrailini-automode-en [2025/12/13 07:47] (current) – [End of day system shutdown] rjversluis | ||
|---|---|---|---|
| Line 165: | Line 165: | ||
| | :!: If not set, this function can cause the loc to reduce from V-Max to V-Mid before returning to V-Max, due to switch settings that need to be verified |\\ | | :!: If not set, this function can cause the loc to reduce from V-Max to V-Mid before returning to V-Max, due to switch settings that need to be verified |\\ | ||
| - | ====Skip signal commands if already set==== | + | |
| - | No command is send to the Command Station if the signal (seemingly) shows the wanted aspect.\\ | + | |
| - | The " | + | |
| - | | :!: If not set, this function can cause the loc to reduce from V-Max to V-Mid before returning to V-Max, due to signal settings that need to be verified |\\ | + | |
| ====Synchronize routes==== | ====Synchronize routes==== | ||
| Force setting one route at a time, regarding the [[# | Force setting one route at a time, regarding the [[# | ||
| Line 352: | Line 349: | ||
| ====End of Day Power Off Delay==== | ====End of Day Power Off Delay==== | ||
| - | Amount of seconds to wait for shutdown and power off the system.\\ | + | Amount of seconds to wait for shutdown and power off the system |
| + | ====End of day system shutdown==== | ||
| + | Shutdown the host system, computer, if the EoD is ready.\\ | ||
| Line 368: | Line 366: | ||
| Accessory events which are no sensors or switches will be regarded as signal events.\\ | Accessory events which are no sensors or switches will be regarded as signal events.\\ | ||
| Enable this option only if manually operated signals, directly on the Command Station, should be displayed correctly in Rocrail.\\ | Enable this option only if manually operated signals, directly on the Command Station, should be displayed correctly in Rocrail.\\ | ||
| + | ====Skip signal commands if already set==== | ||
| + | No command is send to the Command Station if the signal (seemingly) shows the wanted aspect.\\ | ||
| + | The " | ||
| + | | :!: If not set, this function can cause the loc to reduce from V-Max to V-Mid before returning to V-Max, due to signal settings that need to be verified |\\ | ||
| ====Reset signal==== | ====Reset signal==== | ||
| Timer (in seconds) to wait for resetting signals of current block and/or route to red.\\ | Timer (in seconds) to wait for resetting signals of current block and/or route to red.\\ | ||
| Line 406: | Line 407: | ||
| ====CTC Occupancy priority==== | ====CTC Occupancy priority==== | ||
| Default the route color will beset also in case the block has been occupied.\\ | Default the route color will beset also in case the block has been occupied.\\ | ||
| + | |||
| + | ====CTC black on free==== | ||
| + | Use black as fill color in case the object is free,\\ | ||
| + | |||
| + | ====CTC Drag and drop==== | ||
| + | Enable DnD from CTC objects.\\ | ||
| + | |||
| + | |||
rocrailini-automode-en.1734765448.txt.gz · Last modified: 2024/12/21 08:17 by 127.0.0.1