rocrailini-automode-en

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
rocrailini-automode-en [2024/12/21 08:17] – created - external edit 127.0.0.1rocrailini-automode-en [2025/12/13 07:47] (current) – [End of day system shutdown] rjversluis
Line 165: Line 165:
 | :!: If not set, this function can cause the loc to reduce from V-Max to V-Mid before returning to V-Max, due to switch settings that need to be verified |\\ | :!: If not set, this function can cause the loc to reduce from V-Max to V-Mid before returning to V-Max, due to switch settings that need to be verified |\\
  
-====Skip signal commands if already set==== +
-No command is send to the Command Station if the signal (seemingly) shows the wanted aspect.\\ +
-The "InitField" command should be used to synchronize signals at startup.\\ +
-| :!: If not set, this function can cause the loc to reduce from V-Max to V-Mid before returning to V-Max, due to signal settings that need to be verified |\\+
 ====Synchronize routes==== ====Synchronize routes====
 Force setting one route at a time, regarding the [[#route_synchronizer_timeout|Route synchronizer timeout]], to reduce power consumption and switch decoder overload with multiple outputs.\\ Force setting one route at a time, regarding the [[#route_synchronizer_timeout|Route synchronizer timeout]], to reduce power consumption and switch decoder overload with multiple outputs.\\
Line 352: Line 349:
  
 ====End of Day Power Off Delay==== ====End of Day Power Off Delay====
-Amount of seconds to wait for shutdown and power off the system.\\ +Amount of seconds to wait for shutdown and power off the system after the EoD has been finished.\\
  
 +====End of day system shutdown====
 +Shutdown the host system, computer, if the EoD is ready.\\
  
  
Line 368: Line 366:
 Accessory events which are no sensors or switches will be regarded as signal events.\\ Accessory events which are no sensors or switches will be regarded as signal events.\\
 Enable this option only if manually operated signals, directly on the Command Station, should be displayed correctly in Rocrail.\\ Enable this option only if manually operated signals, directly on the Command Station, should be displayed correctly in Rocrail.\\
 +====Skip signal commands if already set==== 
 +No command is send to the Command Station if the signal (seemingly) shows the wanted aspect.\\ 
 +The "InitField" command should be used to synchronize signals at startup.\\ 
 +| :!: If not set, this function can cause the loc to reduce from V-Max to V-Mid before returning to V-Max, due to signal settings that need to be verified |\\
 ====Reset signal==== ====Reset signal====
 Timer (in seconds) to wait for resetting signals of current block and/or route to red.\\ Timer (in seconds) to wait for resetting signals of current block and/or route to red.\\
Line 406: Line 407:
 ====CTC Occupancy priority==== ====CTC Occupancy priority====
 Default the route color will beset also in case the block has been occupied.\\ Default the route color will beset also in case the block has been occupied.\\
 +
 +====CTC black on free====
 +Use black as fill color in case the object is free,\\
 +
 +====CTC Drag and drop====
 +Enable DnD from CTC objects.\\
 +
 +
rocrailini-automode-en.1734765448.txt.gz · Last modified: 2024/12/21 08:17 by 127.0.0.1